Control Data Corporation CYBER 170 Series Operator's Manual page 182

Nos version 1
Table of Contents

Advertisement

~
C')
«=
~
w
en
C')
«=
«=
1:"1'
MESSAGE
BUFFER CONTROL WORD ERROR.
Ccc DO'WNED.
Ccc, MTS FIRMWARE LOAD ERRORS.
Ccc, Tt ATS CONVERSION TABLE LOAD ERRORS •.
or
Ccc, Tt MTS CONVERSION TABLE LOAD ERRORS.
CANNOT ALLOCATE DEVICE.
CANNOT ENABLE
npu.
CANNOT LOAD
CANNOT SEND MESSAGE TO PASSIVE DEVICE
SIGNIFICANCE
Dayfile message indicating that the word
count
in
the disk linkage is greater than
100B.
Magnetic tape channel cc has been logically
turned off by the system.
Unable to load magnetic tape controller
firmware on channel cc.
Errors occurred in loading of conversion
table.
cc
Channel number
t
Conversion table (one of the
following) •.
1
ASCII table
2
EBCDIC table
3
BCD table
Cannot allocate a multispindle device for
one of the following reasons.
Not enough spare spindles available
Spare spindles not up and allocatable
An
attempt was made to allocate a
nonremovable device
The attempt to enable npu failed.
Several attempts to load the NPU were
unsuccessful.
The local operator attempted to send a
message to a passive device (that is, a line
printer,card reader, punch, or plotter).
ACTION
Inform site analyst.
Inform site analyst.
Inform customer engineer.
Inform site analyst.
Perform one of the
following.
-
Decrease pack count
and enter GO.
Enter CLEAR to clear
initialize status for
the device.
Verify that the trunk is
operational.
If npu is
a remote NPU, load its
SAM.
Af
ter you load
SAM, wait for the
message
NPU:
. npu,DI,node
to appear before
entering the ENABLE
command.
Otherwise, no
action is required.
Inform site analyst.
No action is required.
If desired, reenter
command specifying name
of an interactive
(console) device.
ROUTINE
SLL
1MT
lKT
IMT
MSI
NS
NS
CS
I