MESSAGE
CONNECT REJECT, 1fn AT addr.
CONTINUING DESTROYS PFS RECOVERY OF DEVICE
IMPOSSIBLE.
COUPLER ENABLE/DISABLE ILLEGAL
COUPLER ERROR-ec
~-
-'
\
\,- ~-
SIGNIFICANCE
bbbb
Controller status
Unable to connect unit.
System residence was requested for device on
which permanent files reside but device
cannot be recovered as configured.
For
example, all packs of a mu1tispind1e device
are not present in the configuration, packs
are out of order, and so on.
Preceded by
message RECOVERY,dtxx. which indicates the
equipment in error.
The network operator tried to enable or
disable a coupler which is illegal.
An
error was detected in the coupler.
ec
Error code
1
Activated channel empty too
long
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Channel active too long after
function
Channel full after output
Coupler disabled
Coupler not responding
Error retry on input
Channel full after activated on
output
Channel inactive after output
Channel full before function
Interrupt by channel disconnect
Change ·for wait NPU s.tatus too
long
Incorrect coupler status after
write
NPU time-out
Inbound message too large
Memory parity error
Unrecognizable CLA
ACTION
Inform site analyst.
Inform site analyst;
recommended action is
one of the following.
Redeadstart without
system on this
device.
Correct
configuration and
redeadstart.
Type GO to
initialize device
with parameters
defined in label.
Deadstart continues
and permanent files
on device are lost.
If the coupler should
not be used, disable the
NPU associated with the
coupler.
Inform customer
engineer.
\