MESSAGE
LOADING ECS tasknam.
LPxx, ••••
LRxx, ••••
LSxx, ••••
LTxx, ••••
MAGNET DROPPED DURING RECOVERY.
MAGNET TERMINATION/NO TAPE JOBS.
MAINS POWER FAILURE.
MASS STORAGE TABLE OVERFLOW •.
MAX
FIELD LENGTH EXCEEDED, JOB ABORTED.
~
SIGNIFICANCE
An incorrect CMRDECK equipment
definition has been entered
"'-)
A controller or channel malfunction has
occurred
The controlware record xxxx is bad
Informative message.
The transaction
subsystem is loading task tasknam.
Refer to description of corresponding
message beginning with EQ.
Refer to description of corresponding
message beginning with EQ.
Refer to description of
correspon~ing
message beginning with EQ.
Refer to description of corresponding
message beginning with EQ.
Informative message indicating the routine
MAGNET 1 was dropped while attempting
clean-up or recovery of the magnetic tape
subsystem.
Informative message indicating the magnetic
tape subsystem was dropped or aborted with
no tapes assigned.
Bit 36 of the status/control register (bit
o
of the interlock register) is set,
indicating a main power failure.
This
message is preceded in the error log by the
letters SRhh.mm.ss. (CYBER 170 machine) or
IR hh.mm.ss. (CYBER 70 machine) where
hh.mm.ss. is the time at which the
condition was detected.
Operator message indicating that the
computed address of the mass storage table
(MST) is not less ·than 100000B and cannot
be placed in byte
4
of an equipment status
table (EST) entry.
Operator message indicating that the
field length requested by RBF, NS, or
CS has exceeded the maximum field
length allowed.
ACTION
record are known to be
good, inform customer
engineer to check the
controller and channel.
None.
None.
None.
Inform site analyst and
customer engineer.
(For
further explanation and
procedures, refer to
sIc
Register Error
Detection, Appendix F.)
Inform site analyst.
Inform site analyst.
\..
ROUTINE
TAF
MAGNET
MAGNET
SCE
SET,
ICM
RBF,
NS,
CS