t p
....
Il:1o
C»
Q
Il:10-
~
(11
C»
Q
Q
t""
MESSAGE
COUPLER UNAVAILABLE
CPxx, ••••
CPxx, COMPARE ERROR.
CPxx,
FEED
FAILURE.
CPU x P REGISTER PARITY ERROR.
CPUMTR ERROR EXIT.
CRxx, ••••
CRxx, ADVANCE 1 CD,
RE~RD
3 CDS.
SIGNIFICANCE
The coupler defined in the NCF is either
off or not defined in the EST.
Refer to description of corresponding
message beginning with EQ.
Detected compare error on card punch with
EST ordinal xx.
Card punch with EST ordinal xx experiencing
card feed failure.
A central processor P register parity
error was detected on CPU x.
x
CPU number
(0
or
1)
CPUMTR has executed an error exit sequence.
The exit mode condition bits of location
zero of
CMR
contain the conditions causing
CPUMTR to error exit.
Refer to description of corresponding
message beginningwithEQ.
Card reader with EST ordinal xx has
encountered a transmission parity error, an
incomplete data transfer, or a binary
checksum error.
ACTION
Inform site analyst.
Job output must be
repunched via DSD
command RERUN (refer
to sec.tion 3).
Inform customer engineer.
Inform site analyst and
customer engineer.
Inform customer engineer.
Redeadstart is necessary.
1. Move back all cards
in input hopper except
first card in hopper
(in the feed station).
2. Advance this card to
output hopper by
pressing RELOAD
MEMORY while holding
back remaining cards.
(The input hopper
must appear to be
empty to the card
reader.)
3. Place last three
cards from output
hopper in front of
cards in input hopper.
4. Release cards in
input hopper and
press READY switch.
ROUTINE
NS
lCD
lCD
SCE
DSD
lCD