MESSAGE
DEADSTART DEVICE UNDEFINED.
DEFINED DEVICE
ALR~Y
EXISTS.
DETECTED IN CtD.
DETECTED IN DIRECTORY.
DETECTED IN PLD.
DETECTED IN RCt.
SIGNIFICANCE
nn
Retry count; error is considered
irrecoverable after the following
number of retries.
PE
10
~
10
tttt
Device status; implies there was
an incomplete transfer if tttt
does not indicate an error
addr
Physical address at beginning of
b~d
The deadstart device is not defined in the
CMRDECK.
The device as defined during initialization
already exists in the multimainframe
environment.
Error was encountered during the building of
the system library.
Disk resident overlay
(OVL) or absolute (ABS) program is not
formatted correctly.
Deadstart processing
halts when this error is detected.
System file error occurred during the
building of the system library.
Start of
the system library was not found.
Deadstart
processing halts when this error is
detected.
System file error occurred during the
building of the system library.
Disk
resident PP program or central memory
resident PP program is not formatted
correctly. Deadstart processing halts when
this error is detected.
Error was encountered during the building of
the system library.
Central memory resident
overlay (OVL) or absolute (ABS) program is
not formatted correctly.
Deadstart
processing halts when this error is
detected.
ACTION
Rede"adstart and enter
the equipment definition
for the deadstart device
at CMRDECK time.
Remove the duplicate
device from the complex
or change the parameters
for the device being
initialized.
Redeadstart at a
different tape density
or use another tape unit
or a different deadstart
tape.
If the error
persists, inform the
site analyst.
Redeadstart at a
different tape density
or use another tape unit
or a different deadstart
t~pe.
If the error
persists, inform the
site analyst.
Redeadstart at a
different tape density
or use another tape unit
or a different deadstart
tape.
If the error
persists, inform the
site analyst.
Redeadstart at a
different tape density
or use another tape
unit or a different
deadstart tape. If the
error persists, inform
ROUTINE
SET
MSI
SYSEDIT
SYSEDIT
SYSEDIT
SYSEDIT