MESSAGE
INITIALIZE W/O PRESET QF LINK DEVICE
ILLEGAL.
INPUT FILE EMPTY.
INSUFFICIENT FIELD LENGTH.
INSUFFICIENT
FL
FOR CORE RESIDENT TASKS.
INSUFFICIENT
FL
FOR DATA MANAGER.
INSUFFICIENT MEMORY FOR CM RECOVERY.
INSUFFICIENT SUB CONTROL POINTS.
INTERNAL ERROR IN MSI.
INVALID COMMMAND PARAMETER
"--./
~j
SIGNIFICANCE
A full initialize was specified for the link
device which, if allowed to continue, would
destroy ECS resident multimainframe tables.
These tables are assumed to be intact in the
absence of a PRESET command.
The NDL processor attempted to open the
file specified for job input but could not
find any recognizable information.
The NDL processor requires additional
central memory to completely process all
input statements that cause table
generation.
Excessive use of the DEFINE
statement can cause the processor to need
additional table space.
There is not enough field length available
to process central memory resident tasks.
This causes the transaction subsystem to
abort.
The transaction executive requires more
field length at initialization time than is
available.
During a level
3
recovery, not enough free
memory (central memory not assigned to
subsystem jobs) is available as is required
for label MSTs. Recovery is impossible.
There are more central memory resident tasks
defined than sub control points.
MSI encountered an internal condition which
could destroy permanent files.
The network/local operator entered an
invalid parameter.
ACTION
Redeadstart without
initializing the link
device if other machines
are operating in a
multimainframe mode;
otherwise, specify PRESET
in conjunction with the
INITIALIZE command.
Check job structure
or vertfy contents of
the input file.
Rerun the job.
Remove as many NDL
DEFINE statements as
possible from the
input file or add an
RFL statement to the
control statement
portion of the job.
Rerun the job.
Inform site analyst.
IFL= may have to be
increased.
Correct error and
reinitialize executive.
Redeadstart using a level
o
deadstart.
Reinitialize the
transaction executive
and assign more
subcontrol points.
Inform site analyst.
Correct parameter and
reenter command.
\
ROUTINE
SET
NDLMAIN
STORDEF,
STORNAME
TAF
TAF
RMS
TAF
MSI