Control Data Corporation CYBER 170 Series Operator's Manual page 245

Nos version 1
Table of Contents

Advertisement

\.~j
"---_/
c:n
o
,;..
~
c.n
c:n
o
o
t"4
tp
-::a
....
-
"-----/
MESSAGE
NPU npu/OVERLAY TERMINATED
NPU npu/OVERLAY ovl TERMINATED
NPU RECOVERED
NPU RECOVERY IN PROGRESS
NPU UNAVAILABLE
NS CODE LEV=yyy, NCF CODE LEV=xxx
NT ••• '.
NTxx,Ccc, 200 IPS GCR UNIT ON 1X PPS.
NTxx DENSITY MISMATCH.
NTxx DRIVE CONFLICT.
~
~
SIGNIFICANCE
An overlay in the specified NPU was
terminated because of the failure or reload
of a remote NPU.
The network operator terminated the overlay.
npu
Name of the NPU
ovl
3-character identifier of overlay
NS has recovered this NPU.
NS is recovering the NPU but is currently
waiting for response from NAM.
The NPU is not physically available because
of an NPU failure or a coupler failure.
In
the case of a remote NPU, a trunk'may have
failed or all other physical paths to the
host may be inoperative (that is, all NPUs
local to the remote NPU have failed or all
trunks to the remote NPU are inoperative or
disabled).
Informative message indicating that the
code level xxx at which the NCF was created
is not the same as the present code level
yyy of NS.
Refer to description of MT •••• series of
messages.
A 679 magnetic tape unit capable of 6250 cpi
is configured on a system with 1X PPU speed.
6250 cpi operations may not be valid.
xx
EST ordinal of tape unit
cc
Tape unit channel
The tape mounted on magnetic tape unit xx
has a density which cannot be read by this
particular unit.
An input tape of 800 cpi
is mounted on a 1600/6250 cpi unit, or an
input tape of 6250.cpi is mounted on an
800/1600 cpi unit.
A tape with 1600 cpi density is mounted on
magnetic tape unit xx but actual assignment
of the tape to unit xx would result in a
resource deadlock for the job.
ACTION
None.
None.
None.
None.
Wait for NPU to reload.
In the case of a ·remote
NPU, enable a disabled
trunk.
Rerun NDLP to create
new NCF.
Inform site analyst.
Remount the tape on a
tape unit capable of
reading the density, or,
if tape is to be written
instead of read, remount
with write ring in.
Unload the tape and
mount it on a unit with
opposite density (that
is, if the tape is on
an 800/1600 cpi unit,
mount it on a 1600/6250
cpi unit).
\
\
.'----
ROUTINE
NS
NS
NS
NS
NS
NS
1MT
RESEX
RESEX

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CYBER 170 Series and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents