0')
o
"' " '
~
U1
0')
o
o
t"'
~
..;j
-
"'---}
\ )
MESSAGE
EMPTY LOWER DRAWER.
END xX,nn.
END OF DAT TRACK CHAIN.
EQxx Annnn PF RECOVERY ERROR.
EQxx Annnn Ttttt Sssss LINKAGE ERROR.
EQxx,BAD SYSTEM SECTOR.
EQxx BUSY ONID=id.
\ J
"' - --)
SIGNIFICANCE
K-display message indicating that the lower
drawer of the cartridge storage unit should
be emptied.
System dayfile message indicating that the
operator endedBATCHIO equipment xx for nn
copies.
An
attempt to introduce a new shared device
into the multimainframe environment failed.
The machine which preset ECS did not reserve
enough tracks in the DAT chain.
Configuration error status is set by CMS.
In the recovery of mass storage device xx,
an unidentified preserved file or preserved
file with a system sector error was
encountered.
xx
EST ordinal of device being
recovered
nnnn
First track of file
A length or linkage error was detected
while recovering preserved files on
equipment xx.
nnnn
First track of file
tttt
EOI track
5555
EOr sector
An
irrecoverable error occurred during the
reading of the system sector of the print
or punch file.
xx
EST ordinal o,f device.
An
attempt has been made to initialize a
shared device which is still being accessed
by another machine.
xx
EST ordinal of device
id
Machine ID of mainframe on which
device is still active
ACTION
Remove all cartridges
from the octapack on
the lower drawer.
Push the position
swi tch to IN.
None.
Redeadstart removing some
shared. equipment from the
configuration or preset
ECS to accommodate more
shared devices.
Supply dumps of dayfile
and error log to site
analyst.
To alter EOI of the file
and proceed with
recovery, enter
n.GO.
where n is the system
control point number.
To terminate recovery of
the device, enter
n.NOGO.
Inform site analyst.
Clear initialize
request or unload device
on mainframe ide
If the
initialize request is
cleared, CMS must be
dropped from the control
point.
\.
ROUTINE
MSSEXEC.
QAP
CMS,
RMS
REC,
CMS
CMS,
REC
no,
XSP
IMS
Need help?