CJ)
o
~
Co)
U'I
CJ)
o
o
t""
~
\,--
.
\
.
, - - - j
MESSAGE
CANT DISABLE
CANT ENABLE
CARTRIDGE CONFLICT, X=x, Y=y.
RESPOND GO TO ACKNOWLEDGE.
CARTRIDGE WEAR NOTED, X=x, Y=y.
RESPOND GO TO ACKNOWLEDGE.
I
\.,
-
/
CCP
ASSIGNED,PFN=fi1en~m,UN=usernam
CCP FILE MUST BE ATTACHED FOR COMMAND
CCP/LCF CONFIGURATION MISMATCH
CCP NOT AVAlLABLE(,PFN=fi1enam,UN=usernam)
\_~j
\ ,,---
..
,
SIGNIFICANCE
Following an attempt to disable the trunk,
an abnormal response was received.
Following an attempt to enable the trunk,
an abnormal response was received.
K-disp1ay message indicating that the
cartridge storage unit was unable to place
the cartridge into cubicle X=x, Y=y because
another cartridge is already there.
Both
cartridges were placed in the lower I/O
drawer.
x
X coordinate of the cubicle (0-57)
y
Y coordinate of the cubicle (0-36)
K-disp1ay message indicating that the
cartridge in the mass storage transport has
been read with two tracks automatically
corrected.
Normally this indicates wear of
the recording surface.
Schedule the
cartridge for replacement.
This message is
written in the error log file also.
x
X coordinate of the cubicle (0-57)
y
Y coordinate of the cubicle (0-36)
The CCP load file has been attached
following a CCP command or, if not in
response to a CCP command, the NPU load has
started.
fi1enam
Name of CCP load file
usernam
User name under which CCP load
file is stored
The network operator entered an OVERLAY
command but a valid CCP file was not
available.
The line specified in the status message
immediately preceding this diagnostic cannot
be configured because CCP, as installed,
cannot accept a port number as large as that
given in the LCF, or because it does not
include the TIP type given in the LCF.
The Ccp' load file to be used by NS could not
be attached.
If PFN and UN are not shown, a
default CCP file was not specified by the
installation.
If the message
ASSIGN VALID CCP FILE
ACTION
None.
None.
Enter K.m.GO to clear
the message.
Run
ASLABEL to restore the
cartriqge to the
cartridge storage unit
(refer' to the NOS
System Maintenance
Reference Manual).
m Message ordinal
Enter K.m.GO to clear
the message.
m Message ordinal
None.
Assign another CCP file
and reenter the OVERLAY
command.
None.
Either CCP or LCF
must be configured
differently.
Assign another CCP
file.
\
,
ROUTINE
NS
NS
MSSEXEC
MSSEXEC
NS
NS
CS
NS
,---'
Need help?