Control Data Corporation CYBER 170 Series Operator's Manual page 194

Nos version 1
Table of Contents

Advertisement

-
t p
~
c
0)
c
"' "
W
1:11
0)
C
c
t"'
MESSAGE
DEVICE SET OFF - DEVICE UNAVAILABLE.
RESPOND GO TO ACKNOWLEDGE.
DEVICE TURNED OFF.
RESPOND GO TO ACKNOWLEDGE.
DIxx,Ccc,l,sec,ann,Stttt,FNqqqq.
or
DIxx,Ccc,l,sec,ann,Stttt,Uuu Cyyyy Sttss.
SIGNIFICANCE
K-display message indicating that the
cartridge storage unit or mass storage
transport (as indicated by line
1
of this
message) is being used through another
interface, is off-line, is turned off, or is
inoperative.
The EST entry is set to OFF.
. K-display message indicating that the
cartridge storage unit or mass storage
transport (as indicated in line
1
of
message) has its EST entry turned off.
An error has been detected on mass storage
device with EST ordinal xx.
The message as
illustrated indicates a half track 844-21
disk. Any of the following device types can
appear in place of DI: DJ (half track
844-41/44 disk), DK (full track 844-21
disk), DL (full track 844-41/44 disk), DM
(half track 885 disk), or DQ (full track 885
disk).
The nature of the error is
determined by examining each parameter in
the message.
xx
EST ordinal of 844/885 disk
cc
Channel number
1
Link code used to associate multiple
lines of messages occurring for the
same error.
s
Error recovery status (one of the
following)
blank
Status of error (recovered or
unrecovered) has not been
determined
R
Error has been recovered
U
Error is irrecoverable
ec
Error code (one of the following)
PE
Parity error/checkword error
AD
Address. error
a
ST
Device status error
FT
Function timed out with no
response
RS
Device reserved
CR
Controller reserved
NR
Device not ready
Type of operation (one of the
following)
R
Read
W
Write
ACTION
Enter K.m.GO to clear
the message.
m Message ordinal
Call customer engineer
and enter K.m.GO.
On a
cartridge storage unit,
check for cartridges
that are out of position
before using again.
m
Message ordinal
Dump error log dayfile
to printer (refer to
description of ERRLOG,
xx. command), and make
it available to the
customer engineer and/
or site analyst.
ROUTINE
MSSEXEC
MSSEXEC
701

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CYBER 170 Series and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents