Deadstart Panel Params (*P*) Display - Control Data Corporation CYBER 170 Series Operator's Manual

Nos version 1
Table of Contents

Advertisement

I
I
Option
P
2-18
Keyword
PPnn=
PPUnn=
TABLE 2-1. KEYBOARD ENTRIES FOR THE *H* DISPLAY (Contd)
Option
OFF/ON
OFF/ON
Function
Specifies the logical status of one or more peripheral processors.
Values for nn are any octal number in the range 3 through 11
(excluding 10) or 20 through 31. Values for nn can also be in the form
a-b (a through b), where a and b are octal numbers in the range 3
through 11 (excluding 10) or 20 through 31 and a is less than b. PPO, 1,
2, 3, and 10 must be on before you can deadstart the NOS system.
For example, the following entries are valid.
PP4 = OFF
PP5-7 = OFF
The following entries are invalid.
PP2 = OFF
PP7-5 = OFF
PP3-31 = OFF
Specifies the logical status of the indicated physical first level
peripheral processor (PPU). Values for n are any octal number in the
range 1 through 15.
Values for nn can also be of the form a-b (a
through b), where a and b are both octal numbers in the
ran~e
1
through 15 and a is less than b.
CEJ/MEJ=
OFF/ON
Specifies the logical status of CEJ/MEJ. If status is ON, CEJ/MEJ
will be used if present.
CMU=
OFF/ON
Description
If there is no CEJ/MEJ switch or the CEJ/MEJ switch is physically set
to the disable posi tion on the deadstart panel and the logical status is
set to ON (default), an error message display results after the final CR
is pressed for the
cn
options. Refer to Setting the Deadstart Panel
earlier in this section for a description of the error message display.
Specifies
the logical
status
of
the
compare/move
unit
(CMU)
hardware. If the logical status is ON, CMU will be used if present.
Option
Description
Deadstart panel params. Select this option to
change any of the following:
the deadstart
level, the CMRDECK, or deadstart panel
words 12 and 14. The *p* display appears on
the left screen as illustrated in figure 2-21.
further intervention on your part. Additional
options cannot be selected after this entry.
Press BKSP if you wish to return to the *0*
display.
Press
CR
if
you
wish to
cause system
deadstart
processing to continue with no
Table 2-2 shows the keyboard entries that you
can
make
to
change
deadstart
panel
parameters.
*p*
(CR) - ENTER OS LOAD AUTOMATIC
(BS) - RETURN TO *0* DISPLAY
I=x
- INIT/RECOVERY LVL
C=xx
- CMRDECK NUMBER
D=x
- DISPLAY CMRDECK
W12=xxxx -
DIS
PANEL WORD 12
W14=xxxx -
DIS
PANEL WORD 14
Figure 2-21. Deadstart Panel Params (*p*) Display
60435600 L