RERUNxx.t
Terminates
current
operation
on
BATCHIO
equipment defined by EST ordinal xx and reenters
the job in the correct queue at a default queue
priority.
RERUNxx,YY. t
Terminates
current
operation
on
BATCHIO
equipment defined by EST ordinal xx and reenters
the job in the correct queue with a queue priority
specified
by
yyOO (MNPS s yyOO s MXPS).
SKIPxx.
Skips forward one logical record on print file on
equipm ent defined by. EST ordinal xx.
SKIPxx,rr.
Skips forward rr logical records on print file on
equipment defined by EST ordinal xx.
SKIPFxx.
Skips forward one file on print file on equipment
defined by EST ordinal xx.
SKIPFxx,ff.
Skips forward ff files on print file on equipment
defined by EST ordinal xx.
SKIPRUxx,ss.
Skips forward ss sectors on print file on equipment
defined by EST ordinal xx (a sector is lOOS central
memory words); ss is limited to lOS sectors (the
current buffer size) plus the number of sectors
remaining· in the buffer.
If
the buffer was empty,
ss would be limited to 20S sectors. If ss is larger
than the number of sectors remaining in the
buffer, the buffer is filled again and the additional
sectors skipped on the new print file.
For
examp'le, if five sectors remained in the print file
and ss was specified as 10, the remaining five
sectors would be skipped, the buffer filled again,
and five additional sectors skipped.
Printing
resumes at the beginning of a line.
STOPxx.
Stops printing on equipment defined by EST
ordinal xx.
SUPPRESSxx.
Suppresses automatic printer carriage control on
line printer defined by EST ordinal xx. Examine
the I display to determine the correct EST
ordinal.
This command stops the page eject
function
on
the
line
printer
to
provide
a
continuous listing f or the current job.
I
SUBSYSTEM CONTROL COMMANDS
The commands that follow provide control over which
subsystems are to be used. When a system deadstart is
performed,
parameters
specified
in
the
IPRDECK
determine which subsystem will initially be available.
Scheduling
other
subsystems
to
a
control
point
or
terminating a current subsystem depends on your action.
When a subsystem is scheduled to a control point, any job
currently assigned to that control point will be rolled out if
its queue priority is MXPS or less. However, if the job has
a queue priority greater than MXPS, it cannot be rolled out
and the command used to call the subsystem would not be
valid. In this case, either terminate the job (if subsystem
required that control point) or specify another control
point. Under normal circumstances, do not terminate the
job unless you have received specific instructions to do so.
n. CDCffff. tt
Calls
the
CYBER
Database Control System
(CDCS) to control point n. This command is not
valid if a job currently assigned to control point n
has
a
queue
priority
greater
than
MXPS.
CDCffff. tt calls a procedure file named CDCffff
under the system user index, which initiates the
CDCS subsystem.
n. EXPORTL.
Calls Export/Import subsystem to control point n.
This should be the control point immediately
preceding the system (last) control point.
This
command is not· valid if a job currently assigned to
control point n has a queue priority greater than
MXPS.
Activity at the EXPORTL control point
can be monitored on the R display (refer to
. section 4).
The disposition of Export/Import punch files is
controlled by setting sense switches as follows:
Entry
Response
n. ONSW1.
Sends all punch files to local
batch (on site) card punch.
n. ONSW2.
Purge all punch files.
n
Control point number
for EXPORTL.
Sense switch 1 has precedence over sense switch
2.
Export/Import· punch files are ignored if
neither is set.
n.IO.
Calls the BA TCHIO subsystem to control point n.
This should be the second from last control point.
For example, if the system (Iast) control point is
tNot currently used by the system but provided for support of a future product set member.
ttThe characters ffff are optional; if required, installation personnel must supply the one to four alphanumeric characters
. to be used.
.