Machine Faults (continued)
Fault
Fault Title
ID
U1512 48V System
Bus Voltage -
Low
U1700 Board Internal
Error - IPE
U1701 Board Internal
Error - IPE
Troubleshooting: Battery Charger Error and Fault Codes
(Model 04590)
Fault
Controller(s)
Condition/Circuit
Affected
Description
T1
Tthree or more
components on
the machine are
reporting a Bus
Voltage - Low
fault.
T6
Inputs or outputs
in the T6:
precharge
controller are
not working
correctly.
T1
Inputs or
outputs in the
T1: primary
controller are
not working
correctly.
Additional Notes
Service Actions
PTO and the
1.
generator
2.
function of the
starter/generator
is disabled.
3.
4.
5.
6.
Machine is
1.
disabled
2.
3.
Machine is
1.
disabled
2.
Page 3–38
Test the 100A, 58V fuse.
Test the 48V batteries with the engine
Off.
Test the 48V logic relay and wiring.
Verify that all starter/generator
motor-to-controller connections are
good.
Test the starter/generator (test
procedure pending).
Replace and program the
starter/generator (contact an
Authorized Toro Distributor for
assistance).
Test the power supply (fused) at the
controller.
Test the ground at the controller.
Swap the T6: precharge controller
with a known-good unit (contact
an Authorized Toro Distributor for
assistance).
Test the 12V battery voltage.
Swap the T1: primary controller
with a known-good unit (contact
an Authorized Toro Distributor for
assistance).