Toro Greensmaster eTriFlex 3360 Service Manual page 46

Hide thumbs Also See for Greensmaster eTriFlex 3360:
Table of Contents

Advertisement

Machine Faults (continued)
Fault
Fault Title
ID
C10C5 Steering
Feedback
Output - Open
Circuit
C10E3 48V Logic
Enable Relay
Output - Short
to Battery
C10E4 48V Logic
Enable Relay
Output -
Overcurrent
C10E5 48V Logic
Enable Relay
Output - Open
Circuit
C1801 Cutting Unit
Motor - High
Temp Shutdown
Troubleshooting: Battery Charger Error and Fault Codes
(Model 04590)
Fault
Controller(s)
Condition/Circuit
Affected
Description
T1
Open circuit
detected
on steering
feedback output.
T1
Low current
detected on logic
relay output.
Indicates a short
to a high (+)
source.
T1
Overcurrent
detected on logic
relay output.
Indicates short
to ground.
T1
Open circuit
detected on logic
relay output.
T2, T3, T4
The motor
temperature is
greater than
130° C (266° F)
in the indicated
cutting unit.
Additional Notes
Service Actions
1.
2.
3.
4.
The short could
1.
be to battery
voltage or to
2.
another signal
that is in a high
3.
(+) state.
4.
1.
2.
3.
4.
1.
2.
3.
4.
PTO is disabled.
1.
2.
3.
4.
5.
6.
Page 3–10
Check the steering feedback output
circuit wiring and connectors (P01,
P72).
Test the steering feedback output
circuit wiring.
Test the steering input device brake
coil.
Swap the T1: Primary controller
with a known-good unit (contact
an Authorized Toro Distributor for
assistance).
Check the logic relay output circuit
wiring and connectors (P01, P47)
Test the logic relay output circuit wiring.
Test the logic relay.
Swap the T1: Primary controller
with a known-good unit (contact
an Authorized Toro Distributor for
assistance).
Check the logic relay output circuit
wiring and connectors (P01, P47)
Test the logic relay output circuit wiring
to ground.
Test the logic relay.
Swap the T1: Primary controller
with a known-good unit (contact
an Authorized Toro Distributor for
assistance).
Check the logic relay output circuit
wiring and connectors (P01, P47)
Test the logic relay output circuit wiring.
Test the logic relay.
Swap the T1: Primary controller
with a known-good unit (contact
an Authorized Toro Distributor for
assistance).
Let the machine cool off.
Check the reel to bedknife contact and
the condition of the cutting unit.
Reduce the reel speed.
Reduce the mow speed.
Test the 48V ground to the motor.
Swap cutting reel motors between
cutting units. Replace and reprogram
the motor if the fault moves to the new
position (contact an Authorized Toro
Distributor for assistance).
Greensmaster® eTriFlex 3360 and 3370
19239SL Rev B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greensmaster etriflex 3370

Table of Contents