Toro Greensmaster eTriFlex 3360 Service Manual page 73

Hide thumbs Also See for Greensmaster eTriFlex 3360:
Table of Contents

Advertisement

Machine Faults (continued)
Fault
Fault Title
ID
U130E Software
Version
Incompatibility
- Processor
Mismatch
U130F Software
Version
Incompatibility -
Unknown
U1311 Software
Version
Incompatibility
- Li-ion Battery
Controller
U1501 48V System
Logic Voltage -
High
U1502 48V System
Logic Voltage -
Low
U1511 48V System
Bus Voltage -
High
Greensmaster® eTriFlex 3360 and 3370
19239SL Rev B
Fault
Controller(s)
Condition/Circuit
Affected
Description
SC5, SC6,
The software is
SC7
incompatible in
the component
indicated.
T1
The T1: Primary
controller has
detected an
incompatible
software
version.
T1
The Li-ion
battery controller
(SC8) software
is incompatible.
T1
Three or more
components on
the machine are
reporting a Logic
Voltage - High
fault.
T1
Three or more
components on
the machine are
reporting a Logic
Voltage - Low
fault.
T1
Three or more
components on
the machine are
reporting a Bus
Voltage - High
fault.
Additional Notes
Service Actions
Traction is
Update machine software (contact an
disabled.
Authorized Toro Distributor for assistance).
Machine is
Update machine software (contact an
disabled.
Authorized Toro Distributor for assistance).
Machine is
Update machine software (contact an
disabled.
Authorized Toro Distributor for assistance).
1.
PTO and the
generator
2.
function of the
starter/generator
is disabled.
3.
4.
PTO and the
1.
generator
function of the
2.
starter/generator
is disabled.
3.
4.
5.
PTO and the
1.
generator
2.
function of the
starter/generator
is disabled.
3.
4.
Page 3–37
Troubleshooting: Battery Charger Error and
Test the 48V batteries.
Verify that all starter/generator
motor-to-controller connections are
good.
Test the starter/generator (test
procedure pending).
Replace and program the
starter/generator (contact an
Authorized Toro Distributor for
assistance).
Test the 48V batteries with the engine
Off.
Test the 48V logic relay and wiring.
Verify that all starter/generator
motor-to-controller connections are
good.
Test the starter/generator (test
procedure pending).
Replace and program the
starter/generator (contact an
Authorized Toro Distributor for
assistance).
Test the 48V batteries.
Verify that all starter/generator
motor-to-controller connections are
good.
Test the starter/generator (test
procedure pending).
Replace and program the
starter/generator (contact an
Authorized Toro Distributor for
assistance).
Fault Codes (Model 04590)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greensmaster etriflex 3370