Toro Greensmaster eTriFlex 3360 Service Manual page 151

Hide thumbs Also See for Greensmaster eTriFlex 3360:
Table of Contents

Advertisement

Testing the T6: Precharge Controller (Model 04590) (continued)
T6: Precharge Controller Inputs (continued)
Greensmaster® eTriFlex 3360 and 3370
19239SL Rev B
INPUT NUMBER
Precharge
Logic Relay Switch
IN 1
IN 2
IN 3
IN 4
T6: Precharge Controller Outputs
OUTPUT NUMBER
OUT 1
OUT 2
Main Contactor Coil
N/C 1
N/C 2
The machine electrical schematic and wire harness drawings in
A (page A–1)
can be used to identify possible circuit problems between the
controller and the input or output devices (e.g. switches and relays).
When testing for wire harness continuity at the connector for
the controller, take care to not damage the connector pins with
multimeter test leads. If connector pins are enlarged or damaged
during testing, connector repair may be necessary for proper
machine operation.
DESCRIPTION
INPUT NUMBER
On
Not Used
Not Used
Not Used
Not Used
DESCRIPTION
OUTPUT NUMBER
Not Used
(ground)
Not Used
Not Used
IMPORTANT
Page 5–47
Electrical System: Testing the Electrical Components
DESCRIPTION
IN 5
Not Used
IN 6
Not Used
IN 7
Not Used
IN 8
Not Used
AIN1
Not Used
DESCRIPTION
Precharge
Precharge Voltage
to Reel Motors, Lift
Actuators, 3WD
Traction (opt)
Not Used
5 VDC OUT
12 VDC OUT
Not Used
Appendix

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greensmaster etriflex 3370

Table of Contents