Testing the Starter/Generator (continued)
Greensmaster® eTriFlex 3360 and 3370
19239SL Rev B
g292337
A. Gen Current should read 0A while the engine is not running.
B. Start the engine. Gen Current: should read from 3A to 10A (depending
on battery condition) while the engine is running at 2,400 rpm.
7. If the InfoCenter diagnostics inputs report normally and the starter/generator
output is out of range, repair or replace the starter/generator or
starter/generator controller; refer to
(page
5–120). If the starter/generator controller is replaced, update the
machine software; contact an Authorized Toro Distributor.
Figure 46
Generator Assembly (Model 04580)
Page 5–39
Electrical System: Testing the Electrical Components