Machine Faults (continued)
Fault
Fault Title
ID
C1851 Cutting Unit
Motor Bus
Voltage - High
C1852 Cutting Unit
Motor Bus
Voltage - Low
C1861 Cutting Unit
Motor - Over
Current
C1901 Lift/Lower Motor
Controller - High
Temp Shutdown
C190C Lift/Lower Motor
Controller - High
Temp Warning
C1910 Lift/Lower Motor
Speed Sensor -
Out of Range
Greensmaster® eTriFlex 3360 and 3370
19239SL Rev B
Fault
Controller(s)
Condition/Circuit
Affected
Description
T2, T3, T4
The 48V
logic voltage
measures
greater than
67.5V in the
indicated cutting
unit.
T2, T3, T4
The 48V
bus voltage
measures less
than 32V in the
indicated cutting
unit.
T2, T3, T4
An internal over
current condition
is detected in the
indicated cutting
unit.
SC2, SC3,
The temperature
SC4
is greater than
75° C (167° F)
in the indicated
actuator.
SC2, SC3,
The temperature
SC4
is greater than
65°C (149°F)
in the indicated
actuator.
SC2, SC3,
An internal
SC4
sensor has failed
in the indicated
actuator.
Additional Notes
Service Actions
PTO is disabled.
1.
Note: If more
than one Bus
Voltage - High
fault is reported,
2.
go to fault U1511
and follow the
listed service
actions.
3.
4.
PTO is disabled.
1.
Note: If more
2.
than one Bus
Voltage - Low
fault is reported,
go to fault U1512
and follow the
listed service
actions.
PTO is disabled.
1.
2.
Lift/Lower is
1.
disabled.
2.
3.
4.
Lift/Lower speed
1.
reduced until
the actuator
temperature
2.
drops below 65°
C (149° F) or
exceeds 75° C
(167° F).
3.
4.
Lift/Lower is
1.
disabled.
2.
3.
Page 3–13
Troubleshooting: Battery Charger Error and
Swap cutting reel motors between
cutting units. Replace and program
the motor if the fault moves to the new
position (contact an Authorized Toro
Distributor for assistance).
Inspect the harness connectors at
the cutting unit motor for damage,
corrosion, debris, and proper alignment
of the pins inside the connectors.
Test the connectors for 48V with the
engine shut off and the key in the On
position.
Test the power and ground wiring
resistance in the harness connectors.
Test the 48V bus Maxi blade fuse
under the left side cover.
Check the 2 pin, 48V bus connector of
the cutting unit motor.
Cycle the key switch.
Replace and program the motor
(contact an Authorized Toro Distributor
for assistance).
Check for mechanical resistance in
the cutting unit suspension making the
actuator work extra hard.
Replace and program the actuator
(contact an Authorized Toro Distributor
for assistance).
Cycle the key switch.
Use the InfoCenter to calibrate the
actuator.
Check for mechanical resistance in
the cutting unit suspension making the
actuator work extra hard.
Replace and program the actuator
(contact an Authorized Toro Distributor
for assistance).
Cycle the key switch.
Use the InfoCenter to calibrate the
actuator.
Replace and program the actuator
(contact an Authorized Toro Distributor
for assistance).
Cycle the key switch.
Use the InfoCenter to calibrate the
actuator.