Inspecting, Maintaining, and Testing the Batteries (Model 04580) (continued)
Charging the Batteries (Model 04580)
Electrical System: Batteries (Model 04580)
Many locally available battery load testers do not, have any
adjustment on the load that is put on the battery. Results received
from using load testers should follow the recommendations of the
load tester manufacturer.
The batteries may be individually charged with a 12V charger rated for operation
with absorbed glass mat (AGM), valve regulated lead acid (VRLA) batteries. The
voltage of this battery type is slightly lower than flooded lead acid batteries.
Maximum charge voltage should be limited to 14.8 VDC. Maximum charge
current should be limited to 2.4 amps.
Follow the manufacturer's instructions when using a battery charger.
Operating the machine should charge the 12V system and the 48V system
batteries.