Toro Greensmaster eTriFlex 3360 Service Manual page 230

Hide thumbs Also See for Greensmaster eTriFlex 3360:
Table of Contents

Advertisement

Disassembling the Starter/Generator (continued)
Electrical System: Service and Repairs
9. Remove the spring bracket from the starter/generator housing.
Note: If the starter/generator housing/stator requires replacement, the
starter/generator assembly must be replaced. The starter/generator
housing/stator is not available separately.
10. Continue to disassemble the starter/generator if necessary:
g288751
1.
Housing/stator assembly
2.
O−ring
3.
Bearing
4.
Rotor assembly
5.
Bearing
6.
Wave washer
7.
O−ring
Use of the starter/generator rotor tool part number TOR6029 is recommended
for this procedure; refer to
When servicing the starter/generator, use a clean work space with
a non-metal surface. The starter/generator rotor includes very
powerful magnets that can cause the rotor to move unexpectedly
if working on a metal surface. Also, any metallic debris that
gets attracted to the rotor can damage the starter/generator after
assembly.
Figure 103
8.
O−ring
9.
Cover
10.
Flange screw (6 each)
11.
Lip seal
12.
Screw (2 each)
13.
Isolator
14.
Gasket
Generator Rotor Tool (page
IMPORTANT
Page 5–126
2–14).
Greensmaster® eTriFlex 3360 and 3370