Testing the Cutting Unit Lift/Lower Switches (continued)
Electrical System: Testing the Electrical Components
2. Disconnect the battery negative (-) cable at the 12V system battery (model
04580); refer to
Removing and Installing the 12V System Battery (Model
04580) (page
5–105), or unplug the 48V battery disconnect (model 04590);
refer to
48V Battery Disconnect (page
3. Remove the console cover; refer to
Console (page
6–38).
4. Disconnect the wire harness from the switch. Check the switch and the
harness connector for damage or corrosion and clean or repair as necessary.
5. Use a multimeter (ohms setting) to determine whether continuity exists
between the various terminals for each switch position: refer to the
Raise/Lower Switch Testing Reference (page
6. Replace the switch if necessary.
7.
If the switch tests correctly and a circuit problem still exists, check the wire
harnesses; refer to
8. Connect the wire harness to the switch and install the console cover.
9. Connect the battery negative (-) cable at the 12V system battery (model
04580), or connect the 48V battery disconnect (model 04590) before
returning the machine to service.