SC8: Lithium-Ion Battery Controller (Model 04590) (continued)
Electrical System: Electrical System Operation
Note: When the key switch is set to the Off position, the BMS delays
disconnecting the batteries from the machine for approximately 3 seconds
to allow time for all of the other machine controllers to shut down.
Communicates battery information to the machine during operation via the
CAN bus.
Communicates battery information to the battery charger via the CAN bus.
Supplies battery pack signal voltage to the key switch.
Note: With the exception of the lithium-ion battery cables, the only
machine circuit with voltage when the key switch is in the O
the low amperage signal voltage (Pack Sig+) from the BMS to the key
switch.
Refer to
SC8: Lithium-Ion Battery Controller (Model 04590) (page 5–40)
lithium-ion battery controller testing information.
Do not open the lithium-Ion battery controller. There are no
serviceable parts on or in the controller. If you open the controller,
you will void the warranty. The controller is protected by
tamper-alerting devices.
Note: If the SC8: Lithium-Ion Battery Controller is replaced for any reason,
the machine software must be updated; contact an Authorized Toro Distributor
for assistance.