Toro Greensmaster eTriFlex 3360 Service Manual page 55

Hide thumbs Also See for Greensmaster eTriFlex 3360:
Table of Contents

Advertisement

Machine Faults (continued)
Fault
Fault Title
ID
P06E9 Starter/Generator
Timeout
P0A1B Traction
Controller -
Short
P0A2A Traction Motor
- Temperature
Sensor Failure
P0A2F Traction Motor
- High Temp
Warning
P0A36 Starter/Generator
- Temperature
Sensor Failure
P0A3B Starter/Generator
Motor - High
Temp Warning
Greensmaster® eTriFlex 3360 and 3370
19239SL Rev B
Fault
Controller(s)
Condition/Circuit
Affected
Description
T1
The starter
function of the
starter/generator
was engaged for
more than the
maximum time
permitted.
SC5, SC6
Either the
traction
controller FET
has shorted, the
motor phases
have shorted, or
the phase wires
from the motor
to controller
are shorted in
the indicated
controller.
SC5, SC6
The temperature
sensor is out
of the normal
operating range
in the indicated
motor.
SC5, SC6,
The traction
motor
T5
temperature is
greater than:
150° C (302° F)
for (SC5, SC6)
or 120° C (248°
F) for T5.
T6
The
starter/generator
FET and the
motor sensor
fail.
T6
The
starter/generator
temperature is
greater than
120° C (248°
F).
Additional Notes
Service Actions
Starter/Generator
1.
is disabled.
2.
Traction is
1.
disabled.
2.
3.
4.
5.
6.
Traction
1.
performance is
2.
limited.
Traction
1.
performance is
2.
limited.
3.
PTO and
Replace and program the starter/generator
starter/generator
(contact an Authorized Toro Distributor for
is disabled.
assistance).
Starter/Generator
1.
current is limited
on a linear
basis until the
temperature
drops below 120°
2.
C (248° F) or
exceeds 130° C
3.
(266° F).
Note: This fault is
4.
not produced by
a bad sensor.
Page 3–19
Troubleshooting: Battery Charger Error and
Cycle the key switch.
Test the key switch.
Verify that U, V, and W motor phases
are correctly connected.
Test each motor phase to ground.
Check the phase resistance to 48V
bus and 48V ground after the controller
capacitor bank has been de-energized.
Replace and program the traction
motor controller (contact an Authorized
Toro Distributor for assistance).
Cycle the key switch.
Use the InfoCenter to calibrate the
traction motors.
Test the wiring to the motor.
Replace the motor.
For SC5, use the InfoCenter to
calibrate the traction pedal first, then
the traction motors.
For SC6, use the InfoCenter to
calibrate the traction motors.
Reduce the ground speed.
Check for mechanical resistance in the
wheels that would make the motors
work extra hard.
Replace the traction motor.
For SC5 and SC6, use the InfoCenter
to calibrate the traction motors.
For T5, program the traction motor
(contact an Authorized Toro Distributor
for assistance).
Clean the air intake screen on the back
of the starter/generator. Be sure the
starter/generator is pulling air through
the air intake by feeling with your hand
or by testing with a piece of paper.
Let the machine cool.
Reduce the cutting loads by reducing
the reel speed or reducing mow speed.
Replace the starter/generator motor.
Fault Codes (Model 04590)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greensmaster etriflex 3370

Table of Contents