Removing and Installing the Lithium-Ion Batteries (Model 04590) (continued)
Greensmaster® eTriFlex 3360 and 3370
19239SL Rev B
F. Label and disconnect the machine wire harness connectors from the
T6: precharge controller.
G. Remove the 4 fasteners securing the center mounted battery try to the
machine.
The center mounted battery assembly weighs approximately 67
kg (148 lbs). Use an appropriate lift and the lift points provided to
remove the center mounted battery assembly.
H. Raise the center mounted battery assembly approximately 7.5 cm (3
inch). Label and disconnect the negative (–) battery cable from the
bottom of the forward most battery before completely removing the
assembly from the machine; refer to connection D in
I.
Continue to dismantle the center mounted battery assembly as necessary.
J. Check the foam strips for damage or wear and replace them if necessary.
Page 5–117
CAUTION
Electrical System: Batteries (Model 04590)
Figure
96.