Toro Greensmaster eTriFlex 3360 Service Manual page 129

Hide thumbs Also See for Greensmaster eTriFlex 3360:
Table of Contents

Advertisement

Identifying the 48 VDC System Fuses and their Functions
Greensmaster® eTriFlex 3360 and 3370
19239SL Rev B
A group of fuses used to protect the 48 VDC system are located in an open fuse
block under the operator's seat. These are standard blade ATO style fuses.
g287256
1.
10A 80V fuse – SC2:Lift/Lower Actuator 1
(center) power bus
2.
10A 80V fuse – SC3:Lift/Lower Actuator 2
(left) power bus
3.
10A 80V fuse – SC4:Lift/Lower Actuator
3 (right) power bus
4.
Open
On model 04590 machines, an additional 48 VDC fuse located in its own holder
on the machine wire harness to the left of the center (rear) battery set. The
fuse is used to protect the T6:Precharge controller. This is a standard blade
ATO style fuse.
Figure 34
(seat raised)
5.
5A 80V fuse – 48V controller logic
6.
30A 80V fuse – SC7:Steering Motor power
bus
7.
10A 80V fuse – Optional work lights (model
04580) or 48 VDC/12 VDC converter
(model 04590)
8.
10A 80V fuse – Optional work lights (model
04590)
Page 5–25
Electrical System: Testing the Electrical Components

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greensmaster etriflex 3370

Table of Contents