Testing the Lift/Lower Actuators (continued)
Calibrating the Lift/Lower Actuators
Greensmaster® eTriFlex 3360 and 3370
19239SL Rev B
g292215
• Act # Mode should read Off while the actuator is stationary.
• Act # Current should read 0A while the actuator is stationary.
• Move the joystick to the L
# Mode while the actuator is moving. The current required to move the
actuator should appear next to Act # Current while the actuator is moving.
• Move the joystick to the R
# Mode while the actuator is moving. The current required to move the
actuator should appear next to Act # Current while the actuator is moving.
7. If the InfoCenter diagnostics inputs and outputs report normally and the
actuator does not function properly, replace the actuator and update the
machine software; contact an Authorized Toro Distributor.
8. Calibrate the lift/lower actuator: refer to
(page
5–83).
1. Sit in the operator seat and set the key switch on the O
2. Access the InfoCenter Settings > Protected Menus > Enter PIN screen
and enter the machine PIN.
3. Access the InfoCenter Service > Calibration screen.
4. Select Lift-lower for the actuator being calibrated and follow the on-screen
calibration instructions.
Note: If the calibration procedure fails, try calibrating the item again before
continuing to troubleshoot the system.
Figure 77
(left cutting unit lowering)
position. Lower should appear next to Act
OWER
position. Raise should appear next to Act
AISE
Calibrating the Lift/Lower Actuators
Page 5–83
Electrical System: Testing the Electrical Components
position.
N

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greensmaster etriflex 3370