Machine Faults (continued)
Fault
Fault Title
ID
C1822 Cutting Unit
Motor - Stall
C1831 Cutting Unit
Motor Internal
Regulator
Voltage - High
C1832 Cutting Unit
Motor Internal
Regulator
Voltage - Low
C1841 Cutting Unit
Motor Logic
Voltage - High
C1842 Cutting Unit
Motor Logic
Voltage - Low
Troubleshooting: Battery Charger Error and Fault Codes
(Model 04590)
Fault
Controller(s)
Condition/Circuit
Affected
Description
T2, T3, T4
The speed of the
motor is 0 RPM
for more than 3
seconds in the
indicated cutting
unit.
T2, T3, T4
The internal
regulator voltage
is greater than
15V in the
indicated cutting
unit.
T2, T3, T4
The internal
regulator voltage
is less than 10V
in the indicated
cutting unit.
T2, T3, T4
The 48V
logic voltage
measures
greater than
67.5V in the
indicated cutting
unit.
T2, T3, T4
The 48V
logic voltage
measures less
than 32V in the
indicated cutting
unit.
Additional Notes
Service Actions
PTO is disabled.
1.
2.
3.
1.
2.
PTO is disabled.
1.
Note: If this fault
2.
is present on
multiple cutting
3.
unit motors,
check the 48V
logic relay and
connector (P47).
PTO is disabled.
1.
Note: If more
than one Logic
Voltage - High
fault is reported,
2.
go to fault U1501
and follow the
listed service
actions.
3.
4.
PTO is disabled.
1.
Note: If more
2.
than one Logic
Voltage - Low
fault is reported,
go to fault U1502
and follow the
listed service
actions.
Page 3–12
Check the cutting unit and the motor
for mechanical resistance.
Check the bedknife adjustment and
the condition of the reel.
Try spinning the motor without a load.
If it doesn't spin, replace and program
the motor (contact an Authorized Toro
Distributor for assistance).
Cycle the key switch.
Replace and program the motor
(contact an Authorized Toro Distributor
for assistance).
Inspect all cutting unit wiring and
connectors.
Inspect the battery terminals.
Swap cutting reel motors between
cutting units. Replace and program
the motor if the fault moves to the new
position (contact an Authorized Toro
Distributor for assistance).
Swap cutting reel motors between
cutting units. Replace and program
the motor if the fault moves to the new
position (contact an Authorized Toro
Distributor for assistance).
Inspect the harness connectors at
the cutting unit motor for damage,
corrosion, debris, and proper alignment
of the pins inside the connectors.
Test the connectors for 48V with the
engine shut off and the key in the On
position.
Test the power and ground wiring
resistance in the harness connectors.
Check the 48V logic power connection
to the motor.
If the battery voltage is good with
engine shut off but not good with the
engine on, test the starter/generator.