Toro Greensmaster eTriFlex 3360 Service Manual page 192

Hide thumbs Also See for Greensmaster eTriFlex 3360:
Table of Contents

Advertisement

Testing the Traction Pedal Position Sensor (continued)
Calibrating the Traction Pedal Position Sensor
Electrical System: Testing the Electrical Components
5. Replace the traction pedal position sensor if necessary. Ensure the sensor
drive is aligned with the tab on the pedal shaft before tightening the mounting
fasteners.
6. If the traction pedal position sensor tests correctly and a circuit problem still
exists, check the machine wire harness; refer to
7. After testing, connect the machine wire harness and calibrate the traction
pedal position sensor; refer to
(page
5–88).
1. Sit in the operator seat and set the key switch on the O
2. Access the InfoCenter Settings > Protected Menus > Enter PIN screen
and enter the machine PIN.
3. Access the InfoCenter Service > Calibration screen.
4. Select Traction Pedal and follow the on-screen calibration instructions.
Note: If the calibration procedure fails, try calibrating the item again before
continuing to troubleshoot the system.
Calibrating the Traction Pedal Position Sensor
Page 5–88
Appendix A (page
A–1).
position.
N
Greensmaster® eTriFlex 3360 and 3370
19239SL Rev B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greensmaster etriflex 3370

Table of Contents