Toro Greensmaster eTriFlex 3360 Service Manual page 56

Hide thumbs Also See for Greensmaster eTriFlex 3360:
Table of Contents

Advertisement

Machine Faults (continued)
Fault
Fault Title
ID
P0A3C Traction Motor
Controller - High
Temp Warning
P0A3E Starter/Generator
Controller -
High Temp
Warning
P0A44 Traction Motor
Speed - High
P0A54 Traction Motor
Controller -
Over Current
P0A5A Starter/Generator
Current Sensor
Out of Range
Troubleshooting: Battery Charger Error and Fault Codes
(Model 04590)
Fault
Controller(s)
Condition/Circuit
Affected
Description
SC5, SC6,
The temperature
T5
is greater than
90°C (194° F)
in the indicated
traction motor
controller.
T6
The
starter/generator
controller
temperature is
greater than 90°
C (194° F).
The ground
SC5, SC6,
T5
speed is more
than the allowed
maximum speed
of the machine
as measured
by the indicated
traction motor.
SC5, SC6,
The current draw
T5
exceeds the
hardware and
software limits
of the indicated
traction motor.
T6
One of the
sensors
inside the
starter/generator
controller fails.
Additional Notes
Service Actions
Traction motor
1.
current is limited
2.
on a linear
basis until the
temperature
drops below
3.
90°C (194° F)
or exceeds 100°
C (212° F).
4.
5.
Starter/Generator
1.
current is limited
on a linear
basis until the
temperature
drops below 90°
2.
C (194° F) or
exceeds 100° C
3.
(212° F).
Note: This fault is
4.
not produced by
a bad sensor.
Traction is
1.
disabled.
2.
3.
Traction is
1.
disabled.
2.
PTO and
1.
starter/generator
2.
is disabled.
Page 3–20
Reduce the ground speed.
Check for mechanical resistance in the
wheels that would make the motors
work extra hard.
Replace and program the traction
motor controller (contact an Authorized
Toro Distributor for assistance). The T5
controller is part of the motor assembly
and is not replaceable separately.
Cycle the key switch.
Use the InfoCenter to calibrate the
traction motor controller.
For SC5, calibrate the traction pedal
first, then the traction motors.
For SC6, calibrate the traction motors.
Clean the air intake screen on the back
of the starter/generator. Be sure the
starter/generator is pulling air through
the air intake by feeling with your hand
or by testing with a piece of paper.
Let the machine cool.
Reduce the cutting loads by reducing
the reel speed or reducing mow speed.
Replace and program the
starter/generator controller (contact
an Authorized Toro Distributor for
assistance).
Inspect the wiring of the speed
sensors.
Check supply voltage to the speed
sensor.
Replace the traction motor.
For SC5 and SC6, use the InfoCenter
to calibrate the traction motors.
For T5, program the traction motor
(contact an Authorized Toro Distributor
for assistance).
Cycle the key switch to clear the fault.
Contact an Authorized Toro Distributor
or the Toro Technical Assistance
Center and report that this fault
occurred.
Cycle the key switch.
If the fault repeats, replace and
program the starter/generator
controller (contact an Authorized Toro
Distributor for assistance).
Greensmaster® eTriFlex 3360 and 3370
19239SL Rev B