Disassembling the Starter/Generator (continued)
Greensmaster® eTriFlex 3360 and 3370
19239SL Rev B
A. Remove the six flange head screws that secure the cover to the
housing/stator assembly. Do not remove the cover at this time.
B. Secure the base plate of the starter/generator rotor tool (part number
TOR6029) to the drive side of the starter/generator housing/stator with
three 3/8–16 X 3 inch cap screws.
g289007
1.
Generator housing/stator assembly (drive
side)
2.
Generator rotor tool base plate
C. Install the rotor tool shaft into the base plate and turn it in against the
rotor shaft.
The rotor magnets are very powerful and can cause the rotor to
shift position very rapidly during removal. Be cautious during
rotor removal to prevent component damage or personal injury.
D. Turn the rotor tool shaft to push the rotor and cover assembly from the
housing/stator assembly. Support the rotor to prevent it from falling
during removal.
E. Remove the cover from the rotor assembly. Remove the O-rings and the
wave washer from the cover. Discard the O-rings.
F. Remove and discard the O-ring and lip seal from the bearing bore in
the housing.
G. If necessary, remove and discard the bearings from the rotor.
H. If necessary, remove the isolator and gasket from the housing/stator
assembly. Discard the gasket.
11. Inspect the starter/generator components for wear or damage. Replace
components or complete starter/generator assembly if necessary.
Figure 104
3.
Generator rotor tool shaft
CAUTION
Page 5–127
Electrical System: Service and Repairs