To build and start a job queue
1. Power on the Accela Open Autosampler.
The JOB QUEUE display opens
Figure 52. JOB QUEUE
2. Load a sample tray onto an available location in a tray holder or stack. Note the
corresponding tray name.
3. Add a new job for the tray. Press the Add Job key to bring up the default job.
4. For a tray, select the tray name (for example, stk1-01) that corresponds to the location of
the tray you load.
5. Enter the first and last sample number for this job.
6. Select and enter the sample processing method for this job.
7. Press the Home function key (F4) to return to the JOB QUEUE display.
8. To add additional samples that you want to process, repeat steps 2 through 7.
9. If necessary, replace or clean the syringe (liquid versions only), or do both.
Press Menu to see the available options for changing (F1: Change Syringe) and cleaning
(F2: Clean Syringe). To completely remove air bubbles, prime the syringe manually.
10. If processing only one job, select the job with the scroll knob. Press the Start key. In the
Select Job(s) to Process dialog box, select one of the following options:
• All (entire job queue starting from the top)
• Selected (job selected with the cursor bar)
• Resume (continue with the next job after the one that was canceled
(Figure