to the connector on the antenna.
To access the receiver via Ethernet, USB, Bluetooth or WLAN, refer to:
•
Setup via Web Interface over Ethernet and DHCP
•
Setup in a non-DHCP network
•
Install USB drivers
•
Setup via Web Interface over USB
•
Setup via Web Interface over Bluetooth (GR25)
•
Setup via Web Interface over WLAN (GR25)
Setup via Web Interface over Ethernet and DHCP
Setup via Web Interface over Ethernet and DHCP
Step
Description
Start the computer.
1
To connect the instrument to the local LAN supporting DHCP, plug an Ethernet cable with a RJ45 connector into
2
the RJ45 Ethernet port on the back of the instrument.
Connect the other end of the cable with a network device of your LAN, e.g. hub, switch or router.
3
Turn the receiver on.
4
Open a browser window on your computer.
5
Type "GR*******" or "GM******* into the browsers address field, with ******* being the serial number of the
6
receiver. For example, GR1700001 or GM1700001.
The Web interface will now be available. Configure the instrument for all required settings.
7
Setup in a non-DHCP Network
Setup in a non-DHCP network
If the instrument is setup in a non-DHCP network, the web interface can still be accessed using a crossed Ethernet cable.
Step
Description
Start the computer.
1
Connect the crossed Ethernet cable to the computer and the Ethernet port on the back of the receiver.
2
Turn the receiver on.
3
On the computer go Start / Control Panel / Network Connections.
4
5: Getting started
a.
GR/GM receiver
b.
Local network
(LAN)
c.
DHCP server
d.
Ethernet cable
e.
Computers with
Web interface
45