Remote Access Wizard: Configure Tcp/Ip Client; Background Information; Setting Descriptions; Remote Access Wizard: Configure Ntrip Server (Source) - Leica GR30 Online Help Manual

Hide thumbs Also See for GR30:
Table of Contents

Advertisement

Remote access wizard: Configure TCP/IP client

Background Information

The TCP/IP client connection setting allows the receiver to act as a TCP client and connect to a configured IP address and port. This
way no port has to be opened in the firewall on the receiver side to allow clients to connect to the receiver.

Setting Descriptions

The table below describes the settings that can be configured on the Configure TCP/IP client page.
Setting
TCP/IP server address
Data receive time out
TCP/IP port
Press
to go back to the previous wizard step. Press
Press
to cancel and return to Spider and remote access: Overview .

Remote access wizard: Configure Ntrip server (source)

Background Information
This mode allows the receiver to act as the Ntrip Server and to initiate an active connection to an Ntrip site on the Leica Spider site
server or other OWI based tools.
In terms of TCP/IP, the Ntrip server mode is in fact a TCP client mode. As an Ntrip Server, the receiver connects to Leica Spider or
other OWI based tools and allows configuration.
Setting Descriptions
The table below describes the settings that can be configured on the Configure Ntrip server (source) page.
Setting
Description
The IP address or hostname of the Ntrip caster to connect to.
Ntrip caster IP
address
The valid IP range is from 1.0.0.0 to 223.255.255.255.
Enter the TCP/IP port to connect to on the Ntrip caster.
TCP/IP port
If for a Spider / OWI connection no OWI requests are received within the specified time, the
Data receive time
out
connection will be automatically reinitialized. This will help keep the communication channel up
and running, especially when using an instable IP network environment, e.g. mobile networks.
If the timeout value is set to 0 (zero), there will be no automatic reinitialization (default setting).
Enter the mount point to connect this Ntrip source to.
Mount point
The mount point is the identifier for the source on an Ntrip Caster. It is needed for Ntrip source
authentication.
162
Description
Enter the numeric IP address or the hostname of the Server to connect to.
The valid IP range is from 1.0.0.0 to 223.255.255.255.
If for a Spider / OWI connection no OWI requests are received within the specified time, the
connection will be automatically reinitialized. This will help keep the communication channel
up and running, especially when using an instable IP network environment, e.g. mobile
networks.
If the timeout value is set to 0 (zero), there will be no automatic reinitialization (default
setting).
Enter the TCP/IP port on the Server for the receiver to connect to.
to continue to the next wizard step.