Gnss Spider Data Streams - Leica GR30 Online Help Manual

Hide thumbs Also See for GR30:
Table of Contents

Advertisement

8: GNSS Spider / Remote Access
When logging is configured in GNSS Spider and the settings have been uploaded to the receiver, a GNSS Spider logging session
appears in the GNSS management / Logging sessions page and in the Status / Logging sessions page.
The Spider logging session is called __spider (with two _) and is activated by starting the site in GNSS Spider.
Per default the logged MDB data is stored in the folder Data\__spider on the receivers SD card. This folder can be changed in the web
interface configuration. GNSS Spider will still be able to download the files.
Please note that a GNSS Spider logging session is always created with the priority setting high. This means that if other logging
sessions, created via the web interface, are running on the receiver and Smart clean up is activated, the priority setting of the GNSS
Spider site guarantees that the data for this site will be protected before lower priority logging sessions on the receiver.
Logging sessions created in GNSS Spider and uploaded to the receiver can be deactivated by stopping the site in GNSS Spider or by
pressing the deactivate button in the web interface of the GR/GM receiver.

GNSS Spider data streams

Two real time and one raw data stream can be configured on the receiver from an active GNSS Spider site at the same time.
A data stream configured in GNSS Spider is only visible and active on the receiver when the according site in GNSS Spider is started.
When the site is stopped, the data streams are deleted from the receiver. No data streams can be deactivated from GNSS Spider on the
GR/GM receiver.
Data streams created in GNSS Spider and uploaded to the GR/GM receiver can however be deactivated in the web interface of the
receiver.