Background Information; Setting Descriptions; Incoming Data Stream Wizard: Set Streaming Status - Leica GR30 Online Help Manual

Hide thumbs Also See for GR30:
Table of Contents

Advertisement

Background Information

This mode allows the receiver to receive data on a physical serial port.
This page allows the user to change the settings on the instrument's serial port.

Setting Descriptions

The table below describes the settings that can be configured on the Configure serial port page.
Setting
Connected to
Baud rate, Parity, Data
bits, Stop bits
Flow control
Press
to go back to the previous wizard step. Press
Press
to cancel and return to GNSS management: Incoming data streams.

Incoming data stream wizard: Set streaming status

Background Information
An incoming real time data stream can only be activated if GPS and GLO tracking of L2C signals is
disabled.
If you want to activate an incoming real time data stream make sure to first disable the tracking of GPS
and GLO L2C signals.
Setting Descriptions
The table below describes the settings that can be configured on the Set streaming status page.
Setting
Activate data stream
Press
to store the data stream configuration.
Press
to go back to the previous wizard step.
Press
to cancel and return to GNSS management: Incoming data stream.
116
Description
Only available on GR25/50. Select the physical serial port for data transmission
Serial port 1
Serial port 2
For the GR10/30 & GM10/30, Serial port 1 is configured
automatically as there is only one serial port available.
Select the port settings for the communication between the receiver and the serial port.
Defines which kind of handshake is used.
None: No handshake.
RTS/CTS: Handshake in both directions.
Description
Deactivate the data stream if you do not want it to run immediately.
to continue to the next wizard step.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gr50Gm30

Table of Contents