Setting Descriptions; Nivel210 Default Communication Settings; D-Series Ns-Xx/Dmg2 Default Communication Settings - Leica GR30 Online Help Manual

Hide thumbs Also See for GR30:
Table of Contents

Advertisement

Setting Descriptions

The settings on this screen define the input port and parameters for incoming tilt device measurements.
Setting
Device
Data rate
Connected to
The following default settings are used for communication between the Tilt device and receiver. They cannot
be edited.

NIVEL210 default communication settings

Communication setting
Port name
Baud rate
Parity
Data bits
Stop bit
Flow control

D-Series NS-XX/DMG2 default communication settings

Communication setting
Port name
Baud rate
Parity
Data bits
Stop bit
Flow control
The D-Series tilt sensor must be configured to use 9600 Baud, otherwise the GR/GM receiver will not be
108
Description
Select the device. The Leica NIVEL210, the Measurement Specialities D-Series NS-
XX/DMG2 and the Applied Geomechanics MD900-T are the only tilt devices supported by
the GR/GM receiver.
The XX in the name of the device "DSeries NS-XX/DMG2" is a
place holder for different versions corresponding to the
measuring range of the tilt device. Currently, versions with
5°/15°/30° measuring range are available. The different versions
use the same interface and can now all be used together with
RefWorx.
The out of range values for the MD900-T tilt sensor are reported
as the maximum angular range measured by the sensor.
Select the rate at which data is requested from the tilt device.
Only available on the GR25/50.
Select the physical serial port for data transmission
Serial port 1
Serial port 2
For the GR10/30 & GM10/30, Serial port 1 is configured
automatically as there is only one serial port available.
Default setting
Serial Port (P1).
9600
None
8
1
No handshake. The handshake used between the receiver and the tilt device.
Default setting
Serial Port (P1).
9600
Even
8
1
No handshake. The handshake used between the receiver and the tilt device.