Ntrip server connections

If an Ntrip server (source) connects to the Ntrip caster and tries to connect to a non-existing mount point, the Ntrip caster will
return an "Invalid mount point" error message. If the Ntrip server (source) is a GR/GM receiver, it will try to reconnect every
every 10s for 30 minutes.
If an Ntrip server (source) connects to the Ntrip caster and tries to connect to a mount point that is already receiving data from
another Ntrip server (source), the Ntrip caster will return a "Mount point taken" error message. If the Ntrip server (source) is a
GR/GM receiver, it will try to reconnect every 10s for 30 minutes.
If an Ntrip server (source) connects to the Ntrip caster and tries to connect to a mount point using a wrong password, the Ntrip
caster will return an "Authentication failed" error message. If the Ntrip server (source) is a GR/GM receiver, it will not try any
reconnects.
If an Ntrip server (source) is connected to the Ntrip caster and no data is received from the source for more than 15 s, the
Ntrip caster will disconnect the Ntrip server (source). This is necessary as it may happen that an Ntrip server (source)
disconnection may not be done properly, leaving the Ntrip caster assuming that the connection is still available. If the Ntrip
server (source) now tries to reconnect, a "mount point taken" message would be issues and the connection not be allowed. To
prevent this, the connection is regularly checked for data transmission. Please make sure the data stream sent to the Ntrip
caster has a rate higher than 15 s. If the connected Ntrip server (source) is a GR/GM receiver, it will continuously try to
reconnect every 5 s.

Related Topics

Status: Ntrip caster
Ntrip caster: Overview
Ntrip caster: Caster tab
Ntrip caster: Mount points tab
Ntrip caster: Create new mount point
Ntrip

Outgoing data stream wizard: Configure Serial port

Background Information

This mode allows data to streamed out of the physical serial port.
This page allows you to change the settings of the instrument's serial port.
Do not select the connection type Serial Port if you have a radio/modem/phone connected to the
physical serial port. In this case you must select the connection type Radio or GSM/Modem/CDMA -
dialup. The serial port settings for these devices are configured in Receiver settings: Device
Management.

Setting Descriptions

The table below describes the settings that can be configured on the Configure serial port page.
Enter the source password.
The source password, as configured for the selected mount point, is required to authenticate
a stream sending data to the Ntrip caster.
to continue to the next wizard step.