Generator Belt; Dismounting; Handling; Remounting - Suzuki Ignis Service Manual

Rg413
Table of Contents

Advertisement

6H-10 CHARGING SYSTEM

DISMOUNTING

1) Disconnect negative cable (1).
2) Disconnect positive cable (2).
3) Remove retainer (3).
4) Remove battery (4).
5. Body ground bolt
6. Nut

HANDLING

When handling battery, following safety precautions should be
followed:
• Hydrogen gas is produced by battery. A flame or spark near
battery may cause the gas to ignite.
• Battery fluid is highly acidic. Avoid spilling on clothing or
other fabric. Any spilled electrolyte should be flushed with
large quantity of water and cleaned immediately.

REMOUNTING

1) Reverse removal procedure.
2) Torque battery cables to specification.
NOTE:
Check to be sure that ground cable has enough clear-
ance to hood panel by terminal.
Tightening torque
Body ground bolt (a): 8.0 N·m (0.8 kg-m, 6.0 lb-ft)
GENERATOR

GENERATOR BELT

Refer to "WATER PUMP BELT" in Section 6B "ENGINE COOL-
ING".

Advertisement

Table of Contents
loading

Table of Contents