Volkswagen Passat 1995 Official Factory Repair Manual page 1347

Hide thumbs Also See for Passat 1995:
Table of Contents

Advertisement

Function tests
http://ebahn.bentleypublishers.com/vw/servlet/Display?action=Goto&type=repair&id=VW...
If specified values are obtained:
- End diagnosis and switch ignition off.
If specified values are not obtained:
- End diagnosis and let engine continue to run at
idle.
- Check primary voltage
Checking primary voltage
- Disconnect 4-pin harness connector (brown) to
Heated Oxygen Sensor (HO2S) 2 -G108- (2-
- Connect multimeter for voltage measurement to
terminals 3 + 4 of connector to Engine Control
Module (ECM) and measure primary voltage.
Specified value: 0.400 to 0.500 Volts
- Switch ignition off.