Functional description and configuration using Web based Management
7.5 The System menu
Restart System
Click this button to restart the SCALANCE X-200RNA. You must confirm the restart in a
dialog box. During a restart, the SCALANCE X-200RNA is reinitialized, the internal firmware
is reloaded, and the device runs a self-test. The learned entries in the address table are
deleted. You can leave the browser window open while the SCALANCE X-200RNA restarts.
Restore Factory Defaults and Restart
Click this button to restore the factory defaults for the configuration. The protected defaults
are also reset. An automatic restart is triggered.
Note
By resetting all the defaults, the IP address is also lost. A SCALANCE X-200RNA can then
be accessed using the Primary Setup Tool.
7.5.4
System Save & Load
System Save & Load via HTTP
The WBM allows you to store configuration information in an external file on your client PC
or to load such data from an external file from the PC to the SCALANCE X-200RNA. You
can also download both new firmware as well as a new FPGA configuration from suitable
files on your client PC.
Note
Following a firmware update, delete the cache of the Web browser.