Teledyne API - Model T200H/T200M Operation Manual
Option
Option
Number
Communication Cables
60A
60B
60C
60D
USB Port
64A
Concentration Alarm Relays
61
RS-232 Multidrop
62
Other Gas Options
65A
86A
87
Special Features
N/A
N/A
N/A
07270D DCN7141
Description/Notes
For remote serial, network and Internet communication with the analyzer.
Type
Description
Shielded, straight-through DB-9F to DB-25M cable, about
RS-232
1.8 m long. Used to interface with older computers or
code activated switches with DB-25 serial connectors.
Shielded, straight-through DB-9F to DB-9F cable of about
RS-232
1.8 m length.
Patch cable, 2 meters long, used for Internet and LAN
Ethernet
communications.
Cable for direct connection between instrument (rear
USB
panel USB port) and personal computer.
For remote connection
For connection to personal computer. (Separate option only when
Option 64B, Analog Input and USB Com Port not elected).
Issues warning when gas concentration exceeds limits set by user.
Four (4) "dry contact" relays on the rear panel of the instrument. This
relay option is different from and in addition to the "Contact Closures"
that come standard on all TAPI instruments.
Enables communications between host computer and up to eight analyzers.
Multidrop card seated on the analyzer's CPU card.
Each instrument in the multidrop network requres this card and a
communications cable (Option 60B).
Second gas sensor and gas conditioners
Oxygen (O
) Sensor
2
Sample Gas Conditioner (Dryer/NH
stream only. Converts analyzer to dual-conditioner instrument.
Sample Oxygenator for proper operation of the NO
converter. Injects oxygen into sample gas that is depleted of oxygen.
Built in features, software activated
Maintenance Mode Switch, located inside the instrument, places
the analyzer in maintenance mode where it can continue sampling,
yet ignore calibration, diagnostic, and reset instrument commands.
This feature is of particular use for instruments connected to
Multidrop or Hessen protocol networks.
Call Technical Support for activation.
Second Language Switch activates an alternate set of display
messages in a language other than the instrument's default
language.
Call Technical Support for a specially programmed Disk on Module containing
the second language.
Dilution Ratio Option allows the user to compensate for diluted
sample gas, such as in continuous emission monitoring (CEM) where
the quality of gas in a smoke stack is being tested and the sampling
method used to remove the gas from the stack dilutes the gas.
Call Technical Support for activation.
Introduction, Features, and Options
Removal) for sample gas
3
-to-NO catalytic
2
Reference
Section 3.4.8
Section 3.4.8
Section 3.4.8
Section 3.4.8
Sections 3.4.8.2
and 4.11.8
Section 3.4.7
Sections 3.4.8.3
and 4.11.9
Figure 3-23, Figure
3-24 and Sections
3.7.2 and 8.4
(contact Sales)
(contact Sales)
N/A
N/A
Section 4.8.2