Testing the Emergency Engine Stop
Switch at Multifunction Switch
Connectors
Refer to
WIRING HARNESS AND CONNECTORS
subsection for connector locations.
The emergency engine stop switch is wired into
the LH multifunction switch connectors (MG1 and
MG2).
1. Remove gauge support, refer to
GAUGE AND ACCESSORIES
2. Disconnect MG1 and MG2 connectors.
3. Test switch continuity as per following table.
EMERGENCY ENGINE STOP SWITCH PIN-OUT
FUNCTION
PROBE
MG1-3 to
MG2-3
RUN position
MG1-1 to
MG1-2
MG1-3 to
MG2-3
STOP position
MG1-1 to
MG1-2
If switch tests good, test continuity of wiring. Re-
fer to
WIRING DIAGRAM
IGNITION COIL
vmr2006-018-100
Ignition Coil Access
BODY
Refer to
subsection and remove RH inner
fender panel(s) for access to the ignition coil.
vmr2016-134
LIGHTS,
subsection.
RESULT
Open circuit
Close to 0
Open circuit
.
Subsection 03 (IGNITION SYSTEM)
vmr2012-031-002_a
TYPICAL
1. Ignition coil location
Installing the Ignition Coil
Install a new elastic nut and tighten to the speci-
fied torque.
TIGHTENING TORQUE
Ignition coil retaining bolt
Testing the Ignition Coil Input Voltage
1. Disconnect the 3-pin connector from the igni-
IGNITION COIL ACCESS
tion coil. Refer to
tmr2011-026-002_a
1. Ignition coil connector
2. Set emergency engine stop switch to RUN.
3. Turn ignition switch to ON.
4. Read voltage as per following table.
REQUIRED TOOL
FLUKE 115 MULTIMETER
(P/N 529 035 868)
8 N•m ± 1 N•m
(71 lbf•in ± 9 lbf•in)
.
3