Can-Am Renegade 570 2016 Service Manual page 297

Table of Contents

Advertisement

Subsection XX (DIAGNOSTIC AND FAULT CODES)
PCODE
MODULE
P0563
DPS
P0563
ECM
P0601
DPS
P0601
SCM-XMR
P0615
ECM
P0616
ECM
14
DESCRIPTION
system voltage
Rectifier failure, damaged
high
circuit wires or connection.
Damaged regulator.
System voltage
An external battery charger
high
may have been used.
CALIBRATION
DPS not calibrated or
FAULT
damage DPS
Bad checksum
of Calibration
Lost of power on reflash
memory section
Damaged relay,
Danaged start switch,
Starter Relay
damaged circuit wires,
damaged connector,
circuit open
damaged ECM pins.
Damaged relay,
Danaged start switch,
Starter Relay
damaged circuit wires,
circuit shorted
damaged connector,
to ground
damaged ECM pins.
CAUSE
Measure battery voltage with
engine stopped. (Expected
value: 11 to 13 volts)
Measure battery voltage with
engine Running at 3500RPM.
(Expected value: 13 to 14.7 volts)
Check connections
on voltage regulator.
Check ground and positive
connections on battery.
Measure battery voltage with
engine stopped. (Expected
value: 11 to 13 volts)
Measure battery voltage with
engine running. (Expected
value: 13 to 14.7 volts)
Check connections
on voltage regulator.
Check ground and positive
connections on battery.
Check ground on vehicle frame
Try updating the DPS
If an update file is available reflash
the SCM, if not clear the fault, if it
returns, replace the SCM.
Check start button, Check
Run/Stop button, check if free
weeling diode is in the good way.
Disconnect starter solenoid relay
Measure resistance from harness
connector: ECM-L3 to SS2
(Expected value: < 2 ohms)
Measure resistance from harness
connector: MG2-6 to SS1
(Expected value: < 2 ohms)
Measure resistance between
terminals SS1 and SS2. (Expected
value: 3 to 6 ohms)
Check start button, Check
Run/Stop button, check if free
weeling diode is in the good way.
Disconnect starter solenoid relay
Measure resistance from harness
connector: ECM-L3 to SS2
(Expected value: < 2 ohms)
Measure resistance from harness
connector: MG2-6 to SS1
(Expected value: < 2 ohms)
Measure resistance between
terminals SS1 and SS2. (Expected
value: 3 to 6 ohms)