Errdisable Recovery Interval - Cisco Catalyst 3650 series Command Reference Manual

Cisco ios xe everest 16.5.1a
Hide thumbs Also See for Catalyst 3650 series:
Table of Contents

Advertisement

errdisable recovery interval

To specify the time to recover from an error-disabled state, use the errdisable recovery interval command
in global configuration mode. To return to the default setting, use the no form of this command.
errdisable recovery interval timer-interval
no errdisable recovery interval timer-interval
Syntax Description
timer-interval
Command Default
The default recovery interval is 300 seconds.
Command Modes
Global configuration
Command History
Release
Cisco IOS XE 3.3SE
Usage Guidelines
The error-disabled recovery timer is initialized at a random differential from the configured interval value.
The difference between the actual timeout value and the configured value can be up to 15 percent of the
configured interval.
You can verify your settings by entering the show errdisable recovery privileged EXEC command.
Examples
This example shows how to set the timer to 500 seconds:
Device(config)# errdisable recovery interval 500
Time to recover from the error-disabled state. The range is 30 to 86400 seconds.
The same interval is applied to all causes. The default interval is 300 seconds.
Command Reference, Cisco IOS XE Everest 16.5.1a (Catalyst 3650 Switches)
errdisable recovery interval
Modification
This command was introduced.
41

Advertisement

Table of Contents
loading

Table of Contents