Display Radius Scheme - HP HSR6600 Command Reference Manual

Hide thumbs Also See for HSR6600:
Table of Contents

Advertisement

Default
The unit for data flows is byte and that for data packets is one-packet.
Views
RADIUS scheme view
Default command level
2: System level
Parameters
data { byte | giga-byte | kilo-byte | mega-byte }: Specifies the unit for data flows, which can be byte,
kilobyte, megabyte, or gigabyte.
packet { giga-packet | kilo-packet | mega-packet | one-packet }: Specifies the unit for data packets,
which can be one-packet, kilo-packet, mega-packet, or giga-packet.
Usage guidelines
The unit for data flows and that for packets must be consistent with those on the RADIUS server.
Otherwise, accounting cannot be performed correctly.
Examples
# Set the traffic statistics unit for data flows and that for packets to kilobytes and kilo-packets, respectively,
in RADIUS scheme radius1.
<Sysname> system-view
[Sysname] radius scheme radius1
[Sysname-radius-radius1] data-flow-format data kilo-byte packet kilo-packet
Related commands

display radius scheme

display radius scheme
Use display radius scheme to display the configuration of RADIUS schemes.
Syntax
display radius scheme [ radius-scheme-name ] [ slot slot-number ] [ | { begin | exclude | include }
regular-expression ]
Views
Any view
Default command level
2: System level
Parameters
radius-scheme-name: RADIUS scheme name.
slot slot-number: Specifies the RADIUS schemes on the card in the slot represented by the slot-number
argument.
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see Fundamentals Configuration Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
59