Download Print this page

Jog Operation Example - Mitsubishi Electric AJ65BT-D75P2-S3 User Manual

Hide thumbs Also See for AJ65BT-D75P2-S3:

Advertisement

11 MANUAL CONTROL

11.2.5 JOG operation example

Remote station READY signal
D75P2 READY signal
Forward run JOG start signal
[RY(n+1)6, RY(n+1)8]
Axis stop signal
[RY(n+1)3, RY(n+1)4]
[RXn4, RXn5]
BUSY signal
Fig. 11.6 Operation when the stop signal is turned ON during JOG operation
When the "stop signal" is turned ON during JOG operation
When the "stop signal" is turned ON during JOG operation, the JOG operation will
stop by the "deceleration stop" method.
JOG start signals will be ignored while the stop signal is ON.
The operation can be started by turning the stop signal OFF, and turning the JOG
start signal from OFF to ON again.
ON
OFF
[RX(n+7)B]
ON
[RXn0]
OFF
ON
OFF
OFF
ON
OFF
POINT
The D75P2 will not receive a "JOG start signal" while the "stop signal" is ON.
ON
11 - 12
MELSEC-A
A JOG start signal OFF  ON
while the stop signal is ON will be ignored.