7 MEMORY CONFIGURATION AND DATA PROCESS
(7) Flash ROM write
(Set "1" in Cd.9 , using RIWT command
(transient transmission))
Flash ROM
Parameter area (a)
Parameter area (b)
Positioning data area
(No.1 to100)
Positioning start information
area (No.7000)
Positioning start information
area (No.7000 to 7010)
Positioning data area
(No.101 to 600)
PLC CPU + master module
Buffer memory, remote register
Parameter area (a)
Parameter area (b)
Positioning data area
(No.1~100)
Positioning start information area
(No.7000)
Monitor data area
Control data area
PLC CPU memory area
Block transmission area
(7) Flash ROM write 1)
(6) Block transmission request
(7) Flash ROM write 2)
Peripheral device
7 - 10
(6) Block transmission request
(Set data in bufer memory
[5100] to [6109] using RIWT command
(transient transmission)]
D75P2
Parameter area (a)
Parameter area (b)
OS memory
Parameter area (a)
Parameter area (b)
Positioning data area
(No.1 to100)
Positioning start information
area (No.7000)
Positioning start information
area (No.7000 to 7010)
Positioning data area
(No.101 to 600)
(8) Flash ROM request (write)
MELSEC-A
to
Pr.1
Pr.6
Pr.10
to
Pr.25
Pr.45
to
Pr.58
Pr.7
to
Pr.9
Pr.26
to
Pr.44

Advertisement