12 CONTROL AUXILIARY FUNCTIONS
Setting item
Software stroke
Pr.13
limit upper limit
value
Software stroke
Pr.14
limit lower limit
value
Software stroke
Pr.15
limit selection
Software stroke
Pr.16
limit valid/invalid
setting
* Refer to section "5.2 List of parameters" for setting details.
(5) Setting the software stroke limit function
To use the "software stroke limit function", set the required values in the
parameters shown in the following table, and write them to the D75P2.
The set details are validated at the rising edge (OFF
READY signal [RX(n+7)B].
Setting
value
Set the upper limit value of the moveable range.
Set the lower limit value of the moveable range.
Set whether to use the "Current feed value (RWrn+0
to 1, RWrn+8 to 9)" or " Md.30 Machine feed value"
as the "current value".
Set whether the software stroke limit is validated or
1:Valid
invalidated during manual control (JOG operation,
manual pulse generator operation).
(6) Invalidating the software stroke limit
To invalidate the software stroke limit, set the following parameters as shown,
and write them to the D75P2. (Set the value within the range.)
Software stroke limit
Pr.13
upper limit value
(For manual operation, set "0: software stroke limit invalid" in the " Pr.16
Software stroke limit valid/invalid setting".)
The set details are validated at the rising edge (OFF
READY signal [RX(n+7)B].
When the unit is "degree", the software stroke limit checks are not made during
speed control (including speed control of speed/position changeover control) and
during manual control, regardless of the Pr.13 , Pr.14 and Pr.16 setting
values.
REMARK
Parameters are set for each axis.
Setting details
=
Pr.14
12 - 31
MELSEC-A
ON) of the remote station
Factory-set
initial value
2147483647
–2147483648
0: Current feed
0: Invalid
Software stroke limit
lower limit value
ON) of the remote station
value