14
TROUBLESHOOTING
Division of
Error
Error name
error
code
Software stroke
922
limit lower limit
Software stroke
923
limit selection
Software stroke
924
limit valid/invalid
setting
Illegal torque limit
925
setting value
Parameter
Command in-
926
position range
M code ON
927
timing error
Speed
928
changeover
mode error
Interpolation
speed
929
designation
method
Current value
930
update request
error
Manual pulse
931
generator
selection error
Description
 The "software stroke limit lower limit value"
setting in detail parameter 1 is out of the
setting range with "degree" unit.
 The software stroke limit upper limit value is
smaller than the software stroke limit value
with a unit other than "degree."
The setting range of "software stroke limit
selection" in detail parameter 1 is out of the
setting range.
The setting range of the "software stroke limit
valid/invalid setting" in detail parameter 1 is out
of the setting range.
The setting range of the "torque limit setting
value" in detail parameter 1 is out of the setting
range.
The setting range of the "command in-position
range" in detail parameter 1 is out of the setting
range.
The setting range of the "M code ON signal
output timing" in detail parameter 1 is out of the
setting range.
The setting range of the "speed changeover
mode" in detail parameter 1 is out of the setting
range.
The setting range of the "interpolation speed
designation method" in detail parameter 1 is
out of the setting range.
The setting range of the "current feed value
during speed control" in detail parameter 1 is
out of the setting range.
The "manual pulse generator selection" setting
in detail parameter 1 is out of the setting range.
14 - 26
Action at occurrence of error
The D75P2 READY signal [RXn0] is not turned
OFF.