3 SPECIFICATIONS AND FUNCTIONS
Device
No.
RX(n+1)E
Axis 1
Command
RX(n+4)E
Axis 2
in-position
signal
RX(n+1)F
Axis 1
Zero point
RX(n+4)F
Axis 2
return
request flag
RX(n+2)0
Axis 1
Zero point
RX(n+5)0
Axis 2
return
complete
flag
RX(n+2)1
Axis 1
Warning
RX(n+5)1
Axis 2
detection
RX(n+2)2
Axis 1
Speed
RX(n+5)2
Axis 2
change 0
flag
RX(n+2)3
Axis 1
Zero point
RX(n+5)3
Axis 2
absolute
position
overflow flag
RX(n+2)4
Axis 1
Zero point
RX(n+5)4
Axis 2
absolute
position
underflow
flag
RX(n+2)5
Axis 1
ABS data bit
RX(n+5)5
Axis 2
0
RX(n+2)6
Axis 1
ABS data bit
RX(n+5)6
Axis 2
1
RX(n+2)7
Axis 1
Transmissio
RX(n+5)7
Axis 2
n data
READY flag
RX(n+2)8
Axis 1
Restart
RX(n+5)8
Axis 2
acceptance
complete flag
RX(n+7)8 Initial data
processing request
Signal name
OFF: Outside in-position
range
ON: Within in-position
range
OFF: Machine zero point
return complete
ON: Machine zero point
return being
requested
OFF: Before machine
zero point return
completion
ON: After machine zero
point return
completion
OFF: Without axis warning
ON: With axis warning
OFF: New speed value is
other than 0
ON: New speed value is
0
OFF: Overflow not
occurred
ON: Overflow occurred
OFF: Underflow not
occurred
ON: Underflow occurred
OFF: bitOFF
ON: bitON
OFF: bitOFF
ON: bitON
OFF: Trans-mission data
being prepared
ON: Trans-mission data
ready
OFF: Restart not accepted
ON: Restart accepted
OFF: No initial data
processing request
ON: Initial data
processing being
requested
n: Address assigned to the master module by station number setting
1
*
: Updated every 56.8ms. (Not update when processing is completed within 56.8ms.)
2
*
: Refer to section 12.6 for the zero point absolute position.
3
*
: Used for maintenance of the absolute position detection system. Unusable for normal operation.
 This signal turns ON when the remaining distance falls within the
"command in-position range" set in the parameter.
 This signal turns OFF when the axis of the corresponding operation
moves.
 A command in-position check is performed every 56.8ms during position
control.
During speed control or during speed control of speed/position changeover
control, a command in-position check is not performed. (*
 This flag turns ON when any of the following conditions occurs, and turns
OFF at completion of a machine zero point return. (*
(a) When the drive unit READY signal turns OFF
(b) When the remote station READY signal turns ON
(c) When a machine zero point return starts
 This flag turns ON at normal completion of a machine zero point return.
 This flag turns OFF at a machine zero point return start, positioning
operation start, JOG operation start or manual pulse generator operation
start or when the drive unit READY signal turns OFF. (*
 This signal turns ON when an axis warning occurs.
 This signal turns OFF when the axis error is reset. (*1)
 This signal turns ON when Speed change request (RY(n+2)7, RY(n+4)7)
is turned ON at a new speed value of 0.
 This signal turns OFF when Speed change request is turned ON at a new
speed value of other than 0. (*
 This signal turns ON when the zero point absolute position (*
overflown due to a current value change. (*
 This signal turns ON when the zero point absolute position (*
underflown due to a current value change. (*
 This signal indicates the low-order bit of ABS data. (*
 This signal indicates the high-order bit of ABS data. (*
 This signal indicates the preparation condition of transmission data in the
ABS transfer mode. (*
3
)
 This signal indicates a restart acceptance condition.
Initial data processing request
 After power-on or after a hardware reset, the D75P2 turns ON Initial data
request to request initial data setting.
This signal turns OFF when Initial data processing complete (RY(n+7)8)
turns ON.
3 - 19
MELSEC-A
Details
1
)
1
)
1
)
1
)
1
)
1
)
3
)
3
)
2
) has
2
) has